Tank Top Heater - FAQ
Dyna Glo Pro: RMC-TT15 and RMC-TT30
Trouble Possible Cause Corrective Action
Burner(s) Will Not Light:
  1. Valve on propane tank is closed
  2. Propane tank is empty
  3. Heater regulator is closed
  4. Plunger on safety shut-off not depressed
  5. Air trapped in manifold, hose or propane tank
  1. Open valve on propane tank
  2. Refill tank
  3. Turn regulator knob to the high setting
  4. Be sure that safety shut-off plunger is fully depressed while lighting
  5. Bleed air in the unit by holding saftey shut-off plunger for 5 seconds max while lighting
Burner(s) Light and Turn Red but Will Not Stay Lit:
  1. Defective thermocouple
  2. The thermocouple is not secure
  3. Defective safety shut-off valve
  1. Thermocouple needs to be replaced
  2. Turn gas off, be sure thermocouple is secured in place
  3. Safety shut-off valve needs to be replaced
Blue Flame Only - Will Not Turn Red:
  1. It is a new unit
  2. Burner screen broken at the top
  3. The regulator is defective
  4. Dirt or blockage in openings, air inlets or mixing tubes
  5. Burner tube loose on valve
  1. This will go away after the unit is heated up, approx 5 -10 minutes
  2. Burner needs to be replaced
  3. Regulator needs to be replaced
  4. turn gas off, clean air inlets and mixing tubes with pipe cleaner
  5. Be sure wingnut is tightened and secured
Heater is Making a High Pitched Sound:
  1. The heater is still warming up
  2. The gas orifice is dirty
  1. Allow heater to fully warm up, the sound should stop within a couple minutes
  2. Turn gas off, remove orifice and clean with a small wire
Heater Makes A Popping Sound, Roars, Rear Housing of Burner Glows Red - (Back Flash):
  1. Wind entering into back of mixing tube
  2. Dirt/Debris (Insects) in mixing tube just above safte valve
  3. Burner screen damaged
  4. Defective Orifice
  1. Turn gas off, be sure the back of the mixing tube is aimed away from a wind source
  2. Turn gas off, clean mixing tubes with pipe cleaner and low pressure air.
  3. Burner needs to be replaced
  4. Orifice needs to be replaced